Westermo TD-23 Installationshandbuch Seite 28

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 27
28 6179-2203
S25 – Delay To DTR
S25 sets the length of time that the modem will ignore DTR for taking the action specified
by &Dn. Its units are one hundredths of a second for other modes.
Range: 0–255 (0.01 seconds)
Default: 5 (0.05 seconds)
S29 – Flash Dial Modifier Time
S29 sets the length of time, in units of 10 ms, that the modem will go on-hook when it
encounters the flash (!) dial modifier in the dial string. The time can be limited as it is a
country dependent parameter.
Range: 0–255 10 ms intervals
Default: 0 (0 ms) (TD-33/V.90 US Fixed: 70)
S30 – Disconnect Inactivity Timer
S30 sets the length of time, in tens of seconds, that the modem will stay online before dis-
connecting when no data is sent or received. In error-correction mode, any data transmitted
or received will reset the timer. In other modes, any data transmitted will reset the timer.
Range: 0–255 tens of seconds (0–2 550 seconds)
Default: 0 (disabled)
S31 – Bit Mapped Options Status
S31 indicates bit mapped options status.
Bit 0 Single line connect message enable/disable (\Vn)
0 = Messages controlled by S95, Wn and Vn (\V0) (Default)
1 = Single line connect message (\V1)
Bit 1 Auto line speed detection (Nn)
0 = Disabled (N0)
1 = Enabled (N1) (Default)
Bits 2–3 Error correction progress messages (Wn)
0 = DTE speed only (W0)
1 = Full reporting (W1) (Default)
2 = DCE (line) speed only (W2)
Bits 4–5 Not used
0 = (Default)
Bits 6–7 Reserved (Default = 11b)
Seitenansicht 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare