36 6178-2203
S-registers
Below follows a description of the S-registers and its different components. Note that
some parameters can not be changed due to local PTT-regulations in different countries.
Where nothing else is stated the registers are stored by using the AT&W command. Some
registers are read only registers and can not be changed from the DTE.
Values inside {..} describes the valid interval and the unit is written inside parenthesis ().
S0 Number of Rings to Auto-Answer
Sets the number of the rings required before the modem automatically answers a call. Zero disables
auto-answer mode.
Default 2 {0..255} Affected by country setting.
Please also refer to S1
S1 Ring Counter (Read only register)
Incremented each time the modem detects a ring signal. Cleared if no rings occur after a short period
of time.
Please also refer to S0.
S2 Escape Character
S2 holds the decimal value of the ASCII character used as the escape character. The default value
corresponds to an ASCII ‘+’. A value over 127 disables the escape process, i.e.; no escape character
will be recognised.
Default 43 (+) {0..255} (ASCII decimal).
Please also refer to S12, ATO.
S3 Carriage Return Character (Not stored with the AT&W command!)
Sets the command line and result code terminator character.
Default 13 (CR) {0..127} (ASCII decimal).
Please also refer to S4.
S4 Line Feed Character (Not stored with the AT&W command!)
Sets the character recognised as a line feed.
Default 10 (LF) {0..127} (ASCII decimal).
Please also refer to S3.
S5 Backspace Character (Not stored with the AT&W command!)
Sets the character recognised as a backspace. The modem will not recognise the Backspace character
if it is set to a value that is greater than 32.
Default 8 (BS) {0..32} (ASCII decimal).
S6 – Wait Time for Dial Tone
Sets the length of time, in seconds, that the modem will wait before starting to dial after going off-
hook when blind dialling.
Default 3 {0..255} (seconds). Affected by country setting.
S7 – Wait Time For Carrier After Dial
Sets the length of time, in seconds, that the modem will wait for carrier before hanging up.
Default 50 {1-255} (seconds). Affected by country setting.
S8 Pause Time For Dial Delay
Sets the time, in seconds, that the modem must pause when the ”,” dial modifier is encountered in the
dial string.
Default 2 {0-255} (seconds).