13
6616-2202
Diagnostics via Telnet
The EDW-100 provides the user with diagnostics information via a Telnet connection
on port 23.
Information presented to the user is:
Operational mode (UDP, TCP-server or client)
Operational status (Listening for connection (TCP server), connected to host
(TCP server or client), Attempting to connect (TCP client))
The ‘Status’ LED on the EDW-100 will lit during Telnet session.
Below is an description of how to start a Windows Telnet session and get diagnostics
information from the EDW-100.
C:\WINDOWS\System32\telnet.exe
Welcome to Microsoft Telnet Client
Escape Character is 'CTRL+]'
Microsoft Telnet> o 169.254.100.100
1. Start a Telnet session.
2. Connect to EDW-100 by typing ‘o 169.254.100.100’
or the configured IP address of the EDW-100.
3. Login using default username and password
(or your customized settings if configured).
Application modes
The EDW-100 can be setup for use in one of four different application modes:
TCP Server TCP Client UDP … Modbus gateway